{"id":3814,"date":"2025-09-19T06:19:25","date_gmt":"2025-09-19T06:19:25","guid":{"rendered":"https:\/\/honeytek.com\/?p=3814"},"modified":"2026-07-01T02:57:37","modified_gmt":"2026-07-01T02:57:37","slug":"12-essential-honeytek-measurement-tools-for-pv-system-installation-and-maintenance","status":"publish","type":"post","link":"https:\/\/honeytek.com\/de\/12-essential-honeytek-measurement-tools-for-pv-system-installation-and-maintenance\/","title":{"rendered":"12 Essential Honeytek Measurement Tools for PV System Installation and Maintenance"},"content":{"rendered":"<div class=\"product\"><div class=\"product\">\n<p class=\"has-large-font-size wp-block-paragraph\"><strong>Introduction<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Photovoltaic (PV) systems are designed to be durable, efficient, and capable of generating clean energy for decades. However, to keep them operating at their best, <strong>regular inspection and measurement<\/strong> are essential. With the right test and measurement instruments, technicians can ensure system safety, maximize efficiency, and prevent costly downtime.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As a trusted manufacturer of electronic measurement tools, <strong>Honeytek<\/strong> offers a comprehensive range of devices for solar professionals. In this guide, we highlight <strong>12 essential Honeytek tools<\/strong> that support PV system installation, maintenance, and troubleshooting.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">1. Voltage and Current Measurement \u2013 Digital Multimeters<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Honeytek <a href=\"https:\/\/honeytek.com\/de\/product\/hk78g-2000v-trms-auto-range-digital-multimeter\/\" data-type=\"product\" data-id=\"3575\">HK78G<\/a> \u2013 2000V TRMS Auto-Range Digital Multimeter<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK78G.png\" alt=\"\" class=\"wp-image-3505\" style=\"width:506px;height:auto\" srcset=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK78G.png 800w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK78G-300x300.png 300w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK78G-150x150.png 150w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK78G-768x768.png 768w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK78G-600x600.png 600w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK78G-100x100.png 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">For high-voltage solar applications, the <strong>HK78G digital multimeter<\/strong> is a must-have.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key Features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Measures <strong>voltage, current, resistance<\/strong>, and more.<\/li>\n\n\n\n<li>Equipped with a <strong>DC high-voltage probe<\/strong>, capable of measuring up to <strong>2000V<\/strong> in PV systems above 1000V.<\/li>\n\n\n\n<li><strong>Terminal protection<\/strong> prevents test lead mis-insertion for safer operation.<\/li>\n\n\n\n<li>Compact and lightweight for single-hand operation in the field.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Use Case in PV Systems:<\/strong><br>Ideal for safely measuring high-voltage solar strings in large PV installations, ensuring compliance with <strong>CAT III 2000V<\/strong> standards.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">2. AC\/DC Clamp Meters for High Current<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Honeytek <a href=\"https:\/\/honeytek.com\/de\/product\/hk888d-6000-count-trms-2000a-ac-dd-solar-pv-clamp-meter\/\" data-type=\"product\" data-id=\"3160\">HK888D<\/a> \u2013 2000A AC\/DC Clamp Meter<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"600\" height=\"836\" src=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK888D-Solar-power-meter.jpg\" alt=\"\" class=\"wp-image-3156\" style=\"width:460px;height:auto\" srcset=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK888D-Solar-power-meter.jpg 600w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/HK888D-Solar-power-meter-215x300.jpg 215w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <a href=\"https:\/\/honeytek.com\/de\/hk888d-digital-clamp-metersafe-measurement-for-1500v-pv-systems\/\" data-type=\"post\" data-id=\"2381\"><strong>HK888D<\/strong> <\/a>provides wide-range measurement capabilities for both current and voltage in PV systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key Features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Current ranges: <strong>600A \/ 2000A AC\/DC<\/strong>.<\/li>\n\n\n\n<li>Measures voltage, current, and resistance.<\/li>\n\n\n\n<li>Compatible with a <strong>DC high-voltage probe<\/strong> for measuring up to <strong>2000V<\/strong>.<\/li>\n\n\n\n<li>Slim jaw design makes it easy to measure cables in tight spaces.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Application in PV Maintenance:<\/strong><br>Perfect for checking circuit current in PV string systems\u2014whether under load or short-circuit testing conditions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">3. High-Voltage Probes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Honeytek DC High-Voltage Test Probe<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When paired with the HK78G multimeter or HK888D clamp meter, the <strong>Honeytek HV probe<\/strong> ensures safe and accurate high-voltage testing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key Features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Supports <strong>CAT III 2000V<\/strong> measurements.<\/li>\n\n\n\n<li>Designed for safe DC 1500V PV system testing.<\/li>\n\n\n\n<li>Allows technicians to measure current and voltage in battery strings without risk.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">4. Insulation Resistance Testers<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Honeytek HK4432A \/ HK4431 \/ HK4430 \u2013 Electronic Insulation Resistance Testers<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"267\" src=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/Insulation-Testers-Manufacturer-1-1024x267.png\" alt=\"\" class=\"wp-image-2493\" srcset=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/Insulation-Testers-Manufacturer-1-1024x267.png 1024w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/Insulation-Testers-Manufacturer-1-300x78.png 300w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/Insulation-Testers-Manufacturer-1-768x200.png 768w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/Insulation-Testers-Manufacturer-1-1536x400.png 1536w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/Insulation-Testers-Manufacturer-1-800x208.png 800w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/Insulation-Testers-Manufacturer-1.png 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Insulation testers are critical for verifying the condition of cables, wires, transformers, and motors in PV systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Applications:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Preventive Maintenance<\/strong>: Detect insulation degradation early.<\/li>\n\n\n\n<li><strong>Commissioning<\/strong>: Verify insulation before system startup.<\/li>\n\n\n\n<li><strong>Troubleshooting<\/strong>: Identify causes of faults or failures.<\/li>\n\n\n\n<li><strong>Compliance<\/strong>: Meet international electrical safety standards.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading has-ast-global-color-2-color has-text-color has-link-color wp-elements-1\">Honeytek <a href=\"https:\/\/honeytek.com\/de\/product\/hk4432a-6000-counts-portable-insulation-tester\/\" data-type=\"product\" data-id=\"2465\">HK4432A <\/a>\/ <a href=\"https:\/\/honeytek.com\/de\/product\/hk60f-2000-counts-1000v-handheld-insulation-tester-2\/\" data-type=\"product\" data-id=\"2470\">HK4432B<\/a> \/ <a href=\"https:\/\/honeytek.com\/de\/product\/hk60f-2000-counts-1000v-handheld-insulation-tester-2-2\/\" data-type=\"product\" data-id=\"2484\">HK4432C<\/a> \u2013 6,000 Counts Portable Insulation Testers<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Specially designed for PV systems, the <strong>HK4432 series<\/strong> goes beyond standard insulation testing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key Features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PV insulation resistance measurement, even during power generation.<\/li>\n\n\n\n<li>Safe for <strong>CAT III 600V<\/strong> environments.<\/li>\n\n\n\n<li>Can measure insulation resistance and open-circuit voltage up to <strong>2000V DC<\/strong>.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Honeytek A4430 \/ A4431 \u2013 2,000 Counts <a href=\"https:\/\/honeytek.com\/de\/insulation-testers-manufacturer\/\" data-type=\"page\" data-id=\"2490\">Portable Insulation Testers<\/a><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For smaller PV systems up to <strong>600 V<\/strong>, the <strong>A4430\/A4431<\/strong> offers reliable insulation resistance testing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Application:<\/strong><br>Ensures safety and performance in residential and small-scale solar installations.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">5. <a href=\"https:\/\/honeytek.com\/de\/product\/t180-handheld-infrared-thermal-lmaging-camera\/\" data-type=\"product\" data-id=\"3010\">Infrared Thermal Imaging Cameras<\/a><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Honeytek T1180 \/ T185 \u2013 Handheld Thermal Imaging Cameras<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/T185-Handheld-Infrared-Thermal-lmaging-Camera.png\" alt=\"\" class=\"wp-image-3012\" style=\"width:564px;height:auto\" srcset=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/T185-Handheld-Infrared-Thermal-lmaging-Camera.png 800w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/T185-Handheld-Infrared-Thermal-lmaging-Camera-300x300.png 300w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/T185-Handheld-Infrared-Thermal-lmaging-Camera-150x150.png 150w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/T185-Handheld-Infrared-Thermal-lmaging-Camera-768x768.png 768w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/T185-Handheld-Infrared-Thermal-lmaging-Camera-600x600.png 600w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/08\/T185-Handheld-Infrared-Thermal-lmaging-Camera-100x100.png 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Thermal imaging is essential for detecting hot spots, defective connections, or overheating components in PV arrays.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key Features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Temperature range: <strong>-20\u00b0C to 550\u00b0C<\/strong>.<\/li>\n\n\n\n<li>Infrared resolution: <strong>160&#215;120 \/ 256&#215;192<\/strong> options.<\/li>\n\n\n\n<li>Four imaging modes: Infrared, Visible Light, Fusion, and Picture-in-Picture.<\/li>\n\n\n\n<li>Built-in <strong>16GB storage<\/strong> for easy reporting.<\/li>\n\n\n\n<li>Rechargeable battery for extended field use.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Use Case:<\/strong><br>Quickly identify failing solar modules, overheating cables, or faulty inverters before major breakdowns occur.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">6. AC Voltage Detectors<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Honeytek HK16A \/ HK16B \u2013 Non-Contact AC Voltage Detectors<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Safety comes first when working around live electrical systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Key Features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Non-contact voltage detection for safer operation.<\/li>\n\n\n\n<li>LED light provides visibility in dark environments.<\/li>\n\n\n\n<li>Audible and visual alerts when voltage is detected.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Application in PV Systems:<\/strong><br>Used for verifying AC voltage presence in inverters, distribution boxes, and connection points.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Why These Tools Are Essential for PV System Professionals<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Installing and maintaining PV systems involves working with <strong>high voltages (up to 1500V DC)<\/strong> und <strong>high currents<\/strong>. Without the right tools:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Safety risks increase significantly.<\/li>\n\n\n\n<li>Faults may go undetected, leading to reduced efficiency or system failure.<\/li>\n\n\n\n<li>Compliance with safety standards cannot be ensured.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Honeytek\u2019s measurement tools are specifically engineered for PV applications, offering the <strong>accuracy, safety ratings, and rugged design<\/strong> needed for the solar industry.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">FAQs \u2013 Measurement Tools for Solar PV Systems<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1: Why do PV systems require specialized measurement tools?<\/strong><br>A: PV systems operate at higher voltages and currents than typical electrical installations. Tools must meet CAT III or higher standards to safely handle transient overvoltages.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2: Which Honeytek tool is best for high-voltage PV systems?<\/strong><br>A: The <strong>HK78G multimeter<\/strong> und <strong>HK888D clamp meter<\/strong>, when used with the DC high-voltage probe, are ideal for measuring up to 2000V in 1500V PV systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3: Why is insulation resistance testing important in solar installations?<\/strong><br>A: It helps detect early insulation degradation, ensuring system reliability and preventing electrical faults.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4: How can thermal imaging improve PV maintenance?<\/strong><br>A: Thermal cameras like the <strong>T1180\/T185<\/strong> quickly identify hot spots, faulty connections, or overheating equipment that could lead to performance loss.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q5: What safety precautions should be taken when testing PV systems?<\/strong><br>A: Always use instruments rated for <strong>CAT III or higher<\/strong>, wear appropriate PPE, and follow standard safety protocols when measuring live circuits.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Fazit<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">As PV systems grow larger and operate at higher voltages, technicians face greater challenges in installation and maintenance. Using the right measurement tools is critical for <strong>safety, efficiency, and reliability<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Honeytek\u2019s wide range of multimeters, clamp meters, insulation testers, thermal cameras, and voltage detectors provide solar professionals with the confidence to perform accurate and safe measurements in any PV environment.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">Ready to upgrade your toolkit with <strong>professional-grade PV measurement instruments<\/strong>?<br>Explore Honeytek\u2019s full range of clamp meters, multimeters, insulation testers, and thermal cameras today.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#\"><strong>Contact Honeytek Now<\/strong><\/a> to learn more about our reliable, safety-certified solutions for solar PV system installation and maintenance.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>You May Also Be Interested In:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/honeytek.com\/wp-admin\/post.php?post=5670&amp;action=edit\" target=\"_blank\" rel=\"noreferrer noopener\">2026 Digital Moisture Meter Buying Guide<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/honeytek.com\/wp-admin\/post.php?post=2648&amp;action=edit\" target=\"_blank\" rel=\"noreferrer noopener\">5 Best Voltage Tester Manufacturers for Any Electrical Project<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/honeytek.com\/wp-admin\/post.php?post=5249&amp;action=edit\" target=\"_blank\" rel=\"noreferrer noopener\">5 Critical Dimensions When Choosing a Solar PV Multimeter<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/honeytek.com\/wp-admin\/post.php?post=5299&amp;action=edit\" target=\"_blank\" rel=\"noreferrer noopener\">5 Essential Multimeter Measurement Tips Every Solar PV Installer Should Know<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/honeytek.com\/wp-admin\/post.php?post=3956&amp;action=edit\" target=\"_blank\" rel=\"noreferrer noopener\">A4430 vs A4431 Portable Insulation Testers: A Complete Comparison Guide<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction Photovoltaic (PV) systems are designed to be durable, efficient, and capable of generating clean energy for decades. However, to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3815,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1,68],"tags":[129],"class_list":["post-3814","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs","category-news-events","tag-measurement-tools"],"acf":[],"_links":{"self":[{"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/posts\/3814","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/comments?post=3814"}],"version-history":[{"count":4,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/posts\/3814\/revisions"}],"predecessor-version":[{"id":6390,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/posts\/3814\/revisions\/6390"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/media\/3815"}],"wp:attachment":[{"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/media?parent=3814"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/categories?post=3814"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/tags?post=3814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}