{"id":6143,"date":"2026-05-25T11:00:04","date_gmt":"2026-05-25T11:00:04","guid":{"rendered":"https:\/\/honeytek.com\/?p=6143"},"modified":"2026-06-05T11:28:47","modified_gmt":"2026-06-05T11:28:47","slug":"stop-disconnecting-wires-how-the-honeytek-hk588b-clamp-meter-improves-hvac-troubleshooting-efficiency","status":"publish","type":"post","link":"https:\/\/honeytek.com\/de\/stop-disconnecting-wires-how-the-honeytek-hk588b-clamp-meter-improves-hvac-troubleshooting-efficiency\/","title":{"rendered":"How the Honeytek HK588B Clamp Meter Improves HVAC Troubleshooting Efficiency"},"content":{"rendered":"<div class=\"product\"><div class=\"product\">\n<h2 class=\"wp-block-heading\">HVAC Troubleshooting Shouldn&#8217;t Mean Taking Systems Apart<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If you&#8217;re an HVAC technician or electrical maintenance engineer, you&#8217;ve probably experienced situations like these:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A fan coil valve refuses to operate during peak cooling season.<\/li>\n\n\n\n<li>A VFD-driven compressor suddenly stops working.<\/li>\n\n\n\n<li>A cold storage room can&#8217;t reach its target temperature.<\/li>\n\n\n\n<li>Electrical faults appear intermittently and are difficult to diagnose.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">In many cases, finding the root cause requires disconnecting wires, opening panels, or carrying multiple testing instruments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Not only does this waste valuable time, but it can also introduce safety risks and system downtime.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The Honeytek HK588B True RMS Clamp Meter was designed to solve these challenges by combining current measurement, temperature testing, voltage analysis, and electrical troubleshooting functions into a single professional tool.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Why HVAC Professionals Need More Than a Standard Clamp Meter<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Modern HVAC systems are no longer simple motor-and-switch installations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Today&#8217;s equipment commonly includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Variable Frequency Drives (VFDs)<\/li>\n\n\n\n<li>Electronic Expansion Valves<\/li>\n\n\n\n<li>Smart Controllers<\/li>\n\n\n\n<li>Building Automation Systems (BAS)<\/li>\n\n\n\n<li>Variable-Speed Compressors<\/li>\n\n\n\n<li>High-Efficiency EC Motors<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These devices generate complex electrical waveforms that ordinary clamp meters often fail to measure accurately.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is where the HK588B stands out.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">1. Measure AC Current Without Disconnecting Wires<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">One of the most valuable features of any clamp meter is non-intrusive current measurement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The HK588B measures up to 600A AC current simply by clamping around a single conductor.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Benefits:<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2714 No need to break the circuit<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2714 Reduced troubleshooting time<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2714 Improved operator safety<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2714 Ideal for crowded electrical panels<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Whether you&#8217;re checking compressor current draw, blower motors, pumps, or air handling units, the HK588B provides quick and reliable readings.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">2. Built-In Temperature Measurement Eliminates Extra Tools<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Unlike many standard clamp meters, the HK588B includes thermocouple temperature measurement from:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>-20 \u00b0C bis 1000 \u00b0C (-4 \u00b0F bis 1832 \u00b0F)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For HVAC technicians, this means fewer tools in the toolbox and faster diagnostics.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Common Applications:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Supply air temperature<\/li>\n\n\n\n<li>Return air temperature<\/li>\n\n\n\n<li>Chilled water systems<\/li>\n\n\n\n<li>Condenser pipe temperatures<\/li>\n\n\n\n<li>Boiler outlet temperatures<\/li>\n\n\n\n<li>Exhaust duct monitoring<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Instead of carrying a separate thermometer, technicians can perform electrical and temperature testing with one instrument.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">3. LPF Technology for Accurate VFD Current Measurement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Variable Frequency Drives are now everywhere in HVAC systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Unfortunately, standard clamp meters often display unstable readings when measuring VFD output because of high-frequency carrier signals.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The HK588B includes:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">LPF ACA (Low Pass Filter AC Current)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This feature filters high-frequency noise and allows technicians to obtain more stable and accurate current readings.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Typical Scenario<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A cooling tower fan suddenly stops.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Using LPF mode, a technician can quickly determine:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Is the VFD producing output current?<\/li>\n\n\n\n<li>Is the motor receiving power?<\/li>\n\n\n\n<li>Is the fault upstream or downstream?<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Without disconnecting a single wire.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This significantly reduces troubleshooting time.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">4. NCV Detection and Flashlight for Field Work<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Many service calls occur in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mechanical rooms<\/li>\n\n\n\n<li>Electrical closets<\/li>\n\n\n\n<li>Ceiling spaces<\/li>\n\n\n\n<li>Outdoor equipment enclosures<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The HK588B includes practical features that technicians use every day:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Non-Contact Voltage Detection (NCV)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Quickly identify energized conductors without direct contact.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Built-In LED Flashlight<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Provides visibility in dark service environments.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Continuity &amp; Diode Testing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Rapidly verify:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fuses<\/li>\n\n\n\n<li>Solenoids<\/li>\n\n\n\n<li>Heating elements<\/li>\n\n\n\n<li>Wiring connections<\/li>\n\n\n\n<li>Control circuits<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These features help technicians locate faults faster and work more safely.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">5. True RMS Accuracy for Modern Electrical Systems<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Many low-cost clamp meters assume a perfect sine wave.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Real-world electrical systems rarely behave that way.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The HK588B uses:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">True RMS Measurement Technology<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This ensures accurate readings when measuring:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>VFD outputs<\/li>\n\n\n\n<li>Electronic motor drives<\/li>\n\n\n\n<li>Switching power supplies<\/li>\n\n\n\n<li>Variable-speed HVAC equipment<\/li>\n\n\n\n<li>Non-linear electrical loads<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For professionals, accurate data means faster diagnosis and fewer return visits.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Real HVAC Troubleshooting Examples<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Example 1: Cooling Tower Fan Not Running<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Using LPF current mode:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Current = 0A<\/li>\n\n\n\n<li>NCV indicates no output voltage<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Result:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The issue is traced to the contactor or drive, not the motor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">No need to remove motor covers or disconnect wiring.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Example 2: Suspicious Temperature Sensor Reading<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The building controller shows 16\u00b0C.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Using the HK588B thermocouple:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Measured temperature = 19\u00b0C.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Result:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sensor drift is confirmed immediately.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The technician can replace the sensor instead of troubleshooting the entire control system.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Example 3: Night-Time Emergency Service<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Low lighting conditions make troubleshooting difficult.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Using:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>LCD backlight<\/li>\n\n\n\n<li>Integrated flashlight<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Technicians can safely perform measurements without additional lighting equipment.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/09\/HK588B-03.webp\" alt=\"\" class=\"wp-image-4514\" style=\"width:525px;height:auto\" srcset=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/09\/HK588B-03.webp 800w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/09\/HK588B-03-300x300.webp 300w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/09\/HK588B-03-150x150.webp 150w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/09\/HK588B-03-768x768.webp 768w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/09\/HK588B-03-600x600.webp 600w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/09\/HK588B-03-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><a href=\"https:\/\/honeytek.com\/de\/product\/hk588b-2000-counts-600a-ac-cat-iii-600v-ncv-trms-clamp-meter\/\" data-type=\"product\" data-id=\"3641\">HK588B <\/a>vs Standard <a href=\"https:\/\/honeytek.com\/de\/die-besten-stromzangen\/\" data-type=\"page\" data-id=\"3072\">Stromzangen<\/a><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Funktion<\/th><th>Standard Clamp Meter<\/th><th>Honeytek HK588B<\/th><\/tr><tr><td>True RMS<\/td><td>Begrenzt<\/td><td>\u2714 Yes<\/td><\/tr><tr><td>Temperaturmessung<\/td><td>Usually No<\/td><td>\u2714 -20\u00b0C~1000\u00b0C<\/td><\/tr><tr><td>LPF Current Measurement<\/td><td>Nein<\/td><td>\u2714 Yes<\/td><\/tr><tr><td>NCV Detection<\/td><td>Partial<\/td><td>\u2714 Yes<\/td><\/tr><tr><td>Taschenlampe<\/td><td>Rare<\/td><td>\u2714 Yes<\/td><\/tr><tr><td>Sicherheitsbewertung<\/td><td>Varies<\/td><td>\u2714 CAT III 600V<\/td><\/tr><tr><td>HVAC-Friendly Functions<\/td><td>Begrenzt<\/td><td>\u2714 Comprehensive<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Why HVAC Technicians Choose Honeytek<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The best troubleshooting tool is not necessarily the most expensive one.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It&#8217;s the one that helps technicians identify faults quickly, safely, and accurately.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The Honeytek HK588B combines:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Genauigkeit des effektiven Wertes (True RMS)<\/li>\n\n\n\n<li>LPF Current Measurement<\/li>\n\n\n\n<li>Temperaturpr\u00fcfung<\/li>\n\n\n\n<li>NCV Detection<\/li>\n\n\n\n<li>CAT III 600V Safety<\/li>\n\n\n\n<li>Portable Field Design<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">All in a single professional instrument built for HVAC and electrical maintenance applications.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">H\u00e4ufig gestellte Fragen<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What is the difference between HK588A and HK588B?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The HK588B includes temperature measurement functionality, making it more suitable for HVAC service and maintenance applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why is LPF important when measuring VFD systems?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Low Pass Filter technology removes high-frequency switching noise generated by VFDs, resulting in more stable and accurate current readings.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can the HK588B measure compressor current?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes. The meter supports AC current measurements up to 600A, suitable for many HVAC compressors and motors.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Is True RMS necessary for HVAC technicians?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes. Many modern HVAC systems use variable-speed drives and electronic controls that produce non-sinusoidal waveforms. True RMS ensures measurement accuracy.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Is the HK588B safe for commercial HVAC systems?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes. The meter is rated CAT III 600V and designed for professional electrical measurement environments.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Ready to Upgrade Your <a href=\"https:\/\/honeytek.com\/de\/2026-digital-moisture-meter-buying-guide\/\" data-type=\"post\" data-id=\"5670\">HVAC<\/a> Diagnostic Toolkit?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Whether you&#8217;re servicing chillers, VFD-driven compressors, air handling units, cooling towers, or building automation systems, the Honeytek HK588B helps you troubleshoot faster and work more efficiently.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Honeytek is a professional manufacturer of digital multimeters, clamp meters, and electrical testing instruments, offering OEM\/ODM customization and worldwide distributor partnerships.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contact us today to learn more about the HK588B and become a Honeytek distributor in your market.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>HVAC Troubleshooting Shouldn&#8217;t Mean Taking Systems Apart If you&#8217;re an HVAC technician or electrical maintenance engineer, you&#8217;ve probably experienced situations [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":6144,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1,70],"tags":[115,46],"class_list":["post-6143","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs","category-new-products","tag-clamp-meter","tag-digital-multimeter"],"acf":[],"_links":{"self":[{"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/posts\/6143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/comments?post=6143"}],"version-history":[{"count":2,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/posts\/6143\/revisions"}],"predecessor-version":[{"id":6146,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/posts\/6143\/revisions\/6146"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/media\/6144"}],"wp:attachment":[{"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/media?parent=6143"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/categories?post=6143"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/honeytek.com\/de\/wp-json\/wp\/v2\/tags?post=6143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}