{"id":5130,"date":"2025-12-22T13:36:20","date_gmt":"2025-12-22T13:36:20","guid":{"rendered":"https:\/\/honeytek.com\/?p=5130"},"modified":"2025-12-21T14:23:47","modified_gmt":"2025-12-21T14:23:47","slug":"how-to-choose-a-clamp-meter-for-electricians","status":"publish","type":"post","link":"https:\/\/honeytek.com\/pt\/how-to-choose-a-clamp-meter-for-electricians\/","title":{"rendered":"How to Choose a Clamp Meter for Electricians"},"content":{"rendered":"<div class=\"product\"><div class=\"product\">\n<p class=\"wp-block-paragraph\">A clamp meter looks simple: open the jaws, clamp a conductor, read the current. In the field, though, the \u201cright\u201d clamp meter is the one that matches your real workloads\u2014distribution panels, motor circuits, VFD-driven equipment, PV\/ESS, tight control cabinets, long shifts, and high safety expectations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This guide walks through the parameters that actually determine whether a clamp meter will be accurate, safe, and efficient in an electrician\u2019s day-to-day work.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Start With the First Question: What Will You Measure?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Before comparing models, define the circuits you touch most often:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Traditional building loads (lighting, heaters, standard motors)<\/li>\n\n\n\n<li>Industrial distribution (large motors, compressors, busbars)<\/li>\n\n\n\n<li>Modern power electronics (VFDs, UPS, EV chargers)<\/li>\n\n\n\n<li>Solar PV, energy storage systems, DC buses<\/li>\n\n\n\n<li>Maintenance diagnostics (inrush, harmonics symptoms, intermittent faults)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">That single list determines whether you need AC-only or AC+DC, True RMS, higher CAT ratings, or specialty functions like inrush and low-pass filtering.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">AC Only vs AC+DC: Don\u2019t Guess\u2014Match the Site Reality<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">When an <a href=\"https:\/\/honeytek.com\/pt\/product\/hk888a-6000-count-trms-2000a-ac-clamp-meter\/\" data-type=\"link\" data-id=\"https:\/\/honeytek.com\/product\/hk888a-6000-count-trms-2000a-ac-clamp-meter\/\">AC clamp meter <\/a>is usually enough<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If you mainly handle conventional building distribution and <strong>pure AC loads<\/strong> (and you rarely see VFD outputs, rectifiers, or DC systems), an AC clamp meter can cover the basics.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That said, <strong>True RMS AC<\/strong> is still the better choice because many real-world waveforms are not clean sine waves\u2014especially with LED drivers and switching power supplies.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"538\" src=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/12\/\u5fae\u4fe1\u56fe\u7247_20251219222553_258_5-1024x538.webp\" alt=\"clamp Meter\" class=\"wp-image-5131\" srcset=\"https:\/\/honeytek.com\/wp-content\/uploads\/2025\/12\/\u5fae\u4fe1\u56fe\u7247_20251219222553_258_5-1024x538.webp 1024w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/12\/\u5fae\u4fe1\u56fe\u7247_20251219222553_258_5-300x158.webp 300w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/12\/\u5fae\u4fe1\u56fe\u7247_20251219222553_258_5-768x403.webp 768w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/12\/\u5fae\u4fe1\u56fe\u7247_20251219222553_258_5-800x420.webp 800w, https:\/\/honeytek.com\/wp-content\/uploads\/2025\/12\/\u5fae\u4fe1\u56fe\u7247_20251219222553_258_5.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">When you must use <a href=\"https:\/\/honeytek.com\/pt\/product\/hk888d-6000-count-trms-2000a-ac-dd-solar-pv-clamp-meter\/\" data-type=\"link\" data-id=\"https:\/\/honeytek.com\/product\/hk888d-6000-count-trms-2000a-ac-dd-solar-pv-clamp-meter\/\">AC+DC <\/a>+ True RMS Clamp Meter<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If you work around any of the following, <strong>AC+DC with True RMS is a practical requirement<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>VFD\/motor drives<\/li>\n\n\n\n<li>Solar PV and storage (ESS)<\/li>\n\n\n\n<li>UPS systems and rectifiers<\/li>\n\n\n\n<li>EV\/charging infrastructure<\/li>\n\n\n\n<li>DC buses, battery systems, control power with DC loads<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Why it matters: non-sinusoidal current and mixed waveforms can cause non-True-RMS meters to read significantly wrong. And an AC-only clamp meter simply won\u2019t measure DC current.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Field rule:<\/strong> If your customer sites include PV\/ESS, VFDs, UPS, or EV, default to <strong>AC+DC True RMS<\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Current Range and Resolution: \u201cMeasure Big\u201d and \u201cSee Small\u201d<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Maximum current range<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Choose the range based on the largest circuits you expect\u2014then leave margin.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Residential\/light commercial: <strong>400\u2013600 A<\/strong> is common<\/li>\n\n\n\n<li>General electrical field work and mixed sites: <strong>600\u20131000 A<\/strong> is safer<\/li>\n\n\n\n<li>Industrial distribution, large motors, busbar work: <strong>1000 A+<\/strong> preferred<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">If you regularly deal with very high currents (or thick conductors that don\u2019t fit), consider a meter that supports a <strong>flexible current coil<\/strong> to extend measurement (often into the 2000\u20133000 A class).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Resolution (how fine the readings are)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Range tells you whether you can measure the current at all; resolution tells you whether the number is useful.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Checking overloads \/ quick go-no-go: <strong>0.1 A<\/strong> resolution is typically fine<\/li>\n\n\n\n<li>Load balancing, diagnosing abnormal standby draw, trending small changes: <strong>0.01 A<\/strong> (or finer) becomes valuable<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Field rule:<\/strong> If you do troubleshooting (not just checks), prioritize better resolution.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Jaw Size and Jaw Geometry: The Difference Between \u201cFits\u201d and \u201cFrustrating\u201d<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Jaw opening (diameter) should match your conductors<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Think about what you clamp most often:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Typical branch circuits in panels: <strong>25\u201330 mm<\/strong> is usually workable<\/li>\n\n\n\n<li>Main feeders, HVAC, elevators, motor supply cables: <strong>30\u201340+ mm<\/strong> is more comfortable<\/li>\n\n\n\n<li>Thick cables, busbars, parallel conductors: consider <strong>40 mm+<\/strong> or a <strong>flex coil<\/strong> option<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Slim jaws help in tight cabinets<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If you frequently work in dense control panels\u2014tight breaker gaps, crowded distribution boards, narrow wire ducts\u2014look for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Slim jaw arms<\/li>\n\n\n\n<li>Easier one-handed operation<\/li>\n\n\n\n<li>A shape that can reach the conductor without forcing awkward angles<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Field rule:<\/strong> A slightly larger jaw and a slimmer profile often outperform \u201cbigger numbers\u201d on paper.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Safety Ratings: CAT Category Is Not a Marketing Detail<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Electrical measurement is about more than \u201ccan it read voltage.\u201d Your meter must survive transients safely.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Recommended minimums for electricians<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>CAT III 600 V<\/strong>: baseline for most panel and building distribution work<\/li>\n\n\n\n<li><strong>CAT III 1000 V<\/strong> ou <strong>CAT IV 600 V<\/strong>: strongly recommended for service entrances, industrial environments, and higher-energy circuits<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Also confirm the meter\u2019s <strong>maximum voltage rating<\/strong> (commonly 600 V or 1000 V). Do not use an underrated meter in higher-energy locations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Field rule:<\/strong> When in doubt, choose the higher CAT rating\u2014especially for distribution and industrial service work.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Accuracy: What \u201cGood Enough\u201d Looks Like in the Field<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Not every job requires lab-grade numbers, but accuracy affects decisions\u2014especially when diagnosing overheating, nuisance trips, motor loading, or phase imbalance.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Professional field work: aim for <strong>\u00b1(1% to 2% of reading + digits)<\/strong> class specs<\/li>\n\n\n\n<li>Basic maintenance \/ household service: <strong>\u00b12% to 3%<\/strong> may be acceptable<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Accuracy alone isn\u2019t everything\u2014True RMS, stability, and filtering often matter more in modern waveforms.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Features That Actually Save Time on Site<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Below is a practical priority list\u2014features that frequently pay for themselves in faster troubleshooting and fewer return visits.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Must-have functions for most electricians<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>AC\/DC voltage (depending on your environment)<\/li>\n\n\n\n<li>Continuity + resistance<\/li>\n\n\n\n<li>Suspens\u00e3o da recolha de dados<\/li>\n\n\n\n<li>Backlight (and a readable display)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">High-value functions for diagnostics<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Inrush current (INRUSH)<\/strong>: critical for motor starts, compressors, and identifying startup stress<\/li>\n\n\n\n<li><strong>Low-pass filter (LPF \/ VFD mode)<\/strong>: helps stabilize readings on VFD-driven outputs<\/li>\n\n\n\n<li><strong>MIN\/MAX<\/strong>: captures spikes and intermittent loads<\/li>\n\n\n\n<li><strong>Frequency (Hz)<\/strong>: useful for motor supply verification and drive behavior checks<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Convenience and safety boosters<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>NCV (non-contact voltage detection)<\/strong>: quick \u201cis it live?\u201d checks (not a replacement for proper verification)<\/li>\n\n\n\n<li>Work light \/ flashlight<\/li>\n\n\n\n<li>Glove-friendly buttons and selector switch<\/li>\n\n\n\n<li>Auto power-off, clear low-battery indication<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Field rule:<\/strong> If you do motor\/industrial work, prioritize <strong>INRUSH + LPF<\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Durability and Ergonomics: The Hidden Spec That Impacts Productivity<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A clamp meter can have excellent specs and still be the wrong tool if it\u2019s uncomfortable or fragile.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Look for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Drop resistance and protective overmold<\/li>\n\n\n\n<li>Solid rotary switch feel (no vague \u201chalf-clicks\u201d)<\/li>\n\n\n\n<li>Strong jaw hinge and consistent closing<\/li>\n\n\n\n<li>Display visibility from multiple angles<\/li>\n\n\n\n<li>A form factor you can hold steady with one hand<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">If you work long shifts, these details matter as much as the datasheet.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Data Logging and Bluetooth: Useful When You Maintain, Not Just Measure<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Wireless logging and app-based trending are not mandatory for every electrician, but they can be highly valuable for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Preventive maintenance programs<\/li>\n\n\n\n<li>Long-duration current monitoring<\/li>\n\n\n\n<li>Evidence capture for reports and warranty claims<\/li>\n\n\n\n<li>Diagnosing intermittent faults that don\u2019t appear during a quick check<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">If your work includes inspections, maintenance contracts, or facility operations support, \u201csmart\u201d features can reduce repeat site visits.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">A Simple Selection Checklist You Can Use Today<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Use this process to pick the right clamp meter class quickly:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Define waveform and system type<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Any DC, PV\/ESS, UPS, VFD, EV? \u2192 <strong>AC+DC True RMS<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Choose current range<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Everyday distribution work \u2192 <strong>600 A<\/strong><\/li>\n\n\n\n<li>Industrial \/ large motors \u2192 <strong>1000 A+<\/strong> and consider flex coil support<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Match jaw size to conductors<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Branch circuits \u2192 25\u201330 mm<\/li>\n\n\n\n<li>Feeders and motor supply \u2192 30\u201340+ mm<\/li>\n\n\n\n<li>Busbars \/ very thick cables \u2192 larger jaws or flex coil<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Set safety category<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Minimum: <strong>CAT III 600 V<\/strong><\/li>\n\n\n\n<li>Prefer: <strong>CAT III 1000 V<\/strong> ou <strong>CAT IV 600 V<\/strong> for higher-energy environments<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Add functions based on tasks<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Motors: INRUSH<\/li>\n\n\n\n<li>VFD sites: LPF\/VFD mode<\/li>\n\n\n\n<li>Troubleshooting: MIN\/MAX + good resolution (0.01 A)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Common Mistakes to Avoid<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Buying AC-only for sites that include DC or PV\/ESS<\/li>\n\n\n\n<li>Ignoring True RMS when measuring distorted waveforms<\/li>\n\n\n\n<li>Choosing a jaw that can\u2019t fit your most common cable sizes<\/li>\n\n\n\n<li>Under-spec\u2019ing CAT ratings for distribution and service work<\/li>\n\n\n\n<li>Paying for features you won\u2019t use while skipping the ones you need (like INRUSH on motor work)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Perguntas frequentes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Do I really need True RMS?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If your environment includes switching power supplies, VFDs, UPS systems, or modern electronic loads, True RMS is strongly recommended. It improves accuracy when the waveform is not a clean sine wave.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Is NCV enough to confirm a circuit is safe?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. NCV is a useful screening tool, but it does not replace proper test procedures with rated instruments, verified leads, and safe work practices.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What jaw size should I choose for general electrical work?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For mixed field work, 30\u201340 mm is often a practical \u201csweet spot.\u201d If you frequently work on thick feeders or crowded panels, jaw geometry and slimness can matter as much as the maximum opening.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">When should I consider a flexible current coil?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When currents exceed the meter\u2019s jaw capacity, conductors are too large to clamp, or you\u2019re measuring around busbars and bundled cables where a rigid jaw won\u2019t fit.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What CAT rating is appropriate for electricians?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CAT III 600 V is a common minimum for panel work. For service entrances and industrial distribution, CAT III 1000 V or CAT IV 600 V is typically the safer choice.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Selecione um <a href=\"https:\/\/honeytek.com\/pt\/product-category\/multimetro-digital-de-pinca\/\" data-type=\"link\" data-id=\"https:\/\/honeytek.com\/product-category\/digital-clamp-multimeter\/\">Alicate-amper\u00edmetro<\/a> Built for Real Field Work<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If you are sourcing clamp meters for electrical contractors, facility maintenance teams, distributors, or OEM tool programs, choose equipment that aligns with modern jobsite realities: AC+DC systems, distorted waveforms, higher safety categories, and durable daily handling.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Honeytek<\/strong> manufactures digital clamp meters and digital multimeters for professional field use, and we support <strong>OEM\/ODM customization<\/strong> (branding, labels, packaging, feature configuration) for distributors and industrial buyers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You may like these:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/honeytek.com\/pt\/how-to-choose-the-right-jaw-opening-for-your-digital-clamp-meter\/\">How to Choose the Right Jaw Opening for Your Digital Clamp Meter<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/honeytek.com\/pt\/key-specifications-for-choosing-an-industrial-high-current-clamp-meter\/\">Key Specifications for Choosing an Industrial High-Current Clamp Meter<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/honeytek.com\/pt\/how-to-measure-dc-current-in-a-photovoltaic-pv-system-using-a-clamp-meter\/\">How to Measure DC Current in a Photovoltaic (PV) System Using Clamp Meter<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/honeytek.com\/pt\/ac-only-vs-ac-dc-clamp-meters-choosing-the-right-tool-for-your-electrical-applications\/\">AC-Only vs. AC\/DC Clamp Meters: Choosing the Right Tool for Your Electrical Applications<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/honeytek.com\/pt\/accuracy-comparison-of-digital-multimeters-portable-capacitance-meters-and-lcr-meters\/\">Accuracy Comparison of Digital Multimeters, Portable Capacitance Meters, and LCR Meters<\/a><\/li>\n<\/ul>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>A clamp meter looks simple: open the jaws, clamp a conductor, read the current. In the field, though, the \u201cright\u201d [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5131,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1,68],"tags":[115],"class_list":["post-5130","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs","category-news-events","tag-clamp-meter"],"acf":[],"_links":{"self":[{"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/posts\/5130","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/comments?post=5130"}],"version-history":[{"count":2,"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/posts\/5130\/revisions"}],"predecessor-version":[{"id":5133,"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/posts\/5130\/revisions\/5133"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/media\/5131"}],"wp:attachment":[{"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/media?parent=5130"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/categories?post=5130"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/honeytek.com\/pt\/wp-json\/wp\/v2\/tags?post=5130"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}