Honeytek HK235 Series Two-Pole Voltage and Continuity Testers
Models: HK235A · HK235B · HK235C · HK235E · HK235G · HK235F
Confirming the absence of voltage before working live is one step every electrical engineer, maintenance electrician, and panel-builder must get right — every time. Non-contact voltage pens are fast, but by design they rely on an induced field, which makes them prone to false negatives (or false positives) around shielded cable, double-insulated wiring, or high-impedance leakage paths. A result you can actually rely on — one that meets the IEC 61243-3 two-pole verification principle by drawing real load current through the circuit under test — only comes from a proper two-pole tester.
The Honeytek HK235 series is built around exactly that verification logic. All six models share the same rugged platform (250 × 83.5 × 45 mm, 355 g), but scale up from a basic pocket tester to models with True RMS measurement, resistance/insulation testing, and RCD trip testing — letting you choose based on the job in front of you, not just whatever tester happens to be in the van.
Key Advantages
One tool, multiple functions — voltage, continuity, phase sequence, NCV, and a built-in flashlight. Fewer specialized instruments to carry, and less chance of a job stalling because the right tool wasn’t in the bag.
IP65 protection across the entire line
All six models are rated IP65 — dust-tight and protected against water jets — making them suitable for outdoor distribution panels, temporary site power, rooftop PV junction boxes, and other non-clean environments without needing an extra protective sleeve.
CAT III 1000 V / CAT IV 600 V safety rating
This covers everything from the service entrance (CAT IV) down to end-use equipment (CAT III), and it's the first non-negotiable checkbox any experienced engineer looks for when specifying a voltage tester — it's a direct safety and compliance requirement, not a nice-to-have.
Triple certification: VDE, GS, CE
VDE is a recognized European electrical-safety mark, and GS (Geprüfte Sicherheit) means the product has passed third-party testing under Germany's Product Safety Act. Together, this makes the HK235 series a straightforward fit for EU-facing projects, foreign-invested facilities, or general contractors with formal supplier-qualification requirements.
True two-pole measurement — no "ghost voltage" false readings.
Unlike an induction-based pen, a two-pole tester draws actual current from the circuit to confirm voltage is genuinely present, eliminating false triggers caused by capacitive/inductive coupling. That matters most in densely wired control cabinets, near VFDs, or on long cable runs.
Feature Comparison
| Особенность | HK235A | HK235B | HK235C | HK235E | HK235G | HK235F |
|---|---|---|---|---|---|---|
| Отображение | Светодиод | LED+LCD | Светодиод | LED+LCD | 6000-count LCD | 2000-count LCD |
| Среднеквадратичное значение | — | — | — | — | ● | ● |
| Voltage Range | 6–690V | 3V–1000VA / 1200VDC | 3V–1000VA, DC | 3V–1000VAC / 1500V DC | 600mV–1000VDC / 600mV–750VAC | 1000VDC / 750VAC |
| Response Range | 0/40–400Hz | 0/40–1000Hz | 0/40–400Hz | 0/40–1000Hz | 1000Hz | 1000Hz |
| Continuity Test (audible/visual) | ● | ● | ● | ● | — | — |
| Resistance Measurement | — | 0.1k–300kΩ | 0.1k–300kΩ | 0.1k–300kΩ | 60MΩ | 20/200/2000Ω |
| Insulation Voltage Test (250V/500V) | — | — | — | — | — | ● |
| RCD Trip Test | — | — | — | — | ● (30mA@230V) | — |
| Phase Sequence / Single-Pole Test | ● | ● | ● | ● | — | — |
| Capacitance / Frequency / Duty Cycle / Diode Test | — | — | — | — | ● | — |
| Loz DC/AC Low-Impedance Range | — | — | — | — | ● | ● |
| MAX/MIN Recording | — | — | — | — | ● | ● |
| Relative Mode | — | — | — | — | ● | — |
| Data Hold | — | ● | ● | ● | — | — |
| Vibration Alert / Silent Mode | ● | ● | ● | ● | — | — |
| NCV (бесконтактное определение напряжения) | ● | ● | ● | ● | ● | ● |
| Фонарик | ● | ● | ● | ● | ● | ● |
| Аккумулятор | 1.5V(AAA)×2 | 1.5V(AAA)×2 | 1.5V(AAA)×2 | 1.5V(AAA)×2 | 1.5V(AAA)×3 | AAA 3.7V×2 |
| Ingress Protection | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
| Сертификация | VDE, GS, CE | VDE, GS, CE | VDE, GS, CE | VDE, GS, CE | VDE, GS, CE | VDE, GS, CE |
| Overvoltage Category | CAT III 1000V / CAT IV 600V (all models) | |||||
| Size / Weight | 250×83.5×45mm / 355g (all models) |
Frequently Asked Questions
Not entirely — they serve different purposes. A voltage pen is good for a quick first pass, but a two-pole tester's actual-load verification method is inherently more reliable, and IEC 61243-3 specifically calls for two-pole equipment to confirm the absence of voltage. The two are best used together: screen with the pen, confirm with the two-pole tester.
The HK235G provides a single test point (30 mA @ 230 V) for a quick field compliance check. If your project requires a full trip-time curve across multiple current multiples (e.g., ×1/×5 as required under IEC 61008), you'll still need a dedicated RCD test instrument.
IP65 protects against dust ingress and water jets from any direction, which suits damp outdoor environments — but it isn't rated for submersion or prolonged exposure to standing water. Avoid testing in direct rainfall and keep the connector ports dry.