{"id":5309,"date":"2026-02-28T07:58:50","date_gmt":"2026-02-28T07:58:50","guid":{"rendered":"https:\/\/honeytek.com\/?p=5309"},"modified":"2026-03-05T02:03:47","modified_gmt":"2026-03-05T02:03:47","slug":"how-to-measure-insulation-resistance-with-a-multimeter-megger-test","status":"publish","type":"post","link":"https:\/\/honeytek.com\/ru\/how-to-measure-insulation-resistance-with-a-multimeter-megger-test\/","title":{"rendered":"How to Measure Insulation Resistance with a Multimeter"},"content":{"rendered":"<div class=\"product\"><div class=\"product\">\n<p class=\"wp-block-paragraph\">Unlike standard resistance measurements, testing&nbsp;<strong>Insulation Resistance (IR)<\/strong>&nbsp;involves injecting high voltage (often 500V or 1000V) into a circuit to stress-test the dielectric material. It is one of the most critical tests for maintenance, but because it turns your meter into a voltage source, the safety risks are significantly higher than using a standard digital multimeter (DMM).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This guide outlines the&nbsp;<strong>Standard Operating Procedure (SOP)<\/strong>&nbsp;for conducting safe, accurate insulation tests, highlighting the specific capabilities of&nbsp;<strong>Honeytek\u2019s Insulation Multimeters<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"538\" src=\"https:\/\/honeytek.com\/wp-content\/uploads\/2026\/02\/How-to-Detect-Industrial-VFD-Faults-Without-Interrupting-Power-Supply-1024x538.webp\" alt=\"\" class=\"wp-image-5311\" srcset=\"https:\/\/honeytek.com\/wp-content\/uploads\/2026\/02\/How-to-Detect-Industrial-VFD-Faults-Without-Interrupting-Power-Supply-1024x538.webp 1024w, https:\/\/honeytek.com\/wp-content\/uploads\/2026\/02\/How-to-Detect-Industrial-VFD-Faults-Without-Interrupting-Power-Supply-300x158.webp 300w, https:\/\/honeytek.com\/wp-content\/uploads\/2026\/02\/How-to-Detect-Industrial-VFD-Faults-Without-Interrupting-Power-Supply-768x403.webp 768w, https:\/\/honeytek.com\/wp-content\/uploads\/2026\/02\/How-to-Detect-Industrial-VFD-Faults-Without-Interrupting-Power-Supply-800x420.webp 800w, https:\/\/honeytek.com\/wp-content\/uploads\/2026\/02\/How-to-Detect-Industrial-VFD-Faults-Without-Interrupting-Power-Supply.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Phase 1: Pre-Test Safety Preparation (The &#8220;Kill&#8221; Step)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Trustworthiness (T):<\/strong>&nbsp;<em>Never skip this phase. 90% of accidents happen here.<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Confirm Total De-energization<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Cut the Power:<\/strong>&nbsp;Disconnect all relevant power sources (inverters, distribution box switches, mains breakers).<\/li>\n\n\n\n<li><strong>LOTO (Lock Out, Tag Out):<\/strong>&nbsp;Hang a sign reading&nbsp;<em>&#8220;Men Working, Do Not Operate&#8221;<\/em>&nbsp;on the switchgear.<\/li>\n\n\n\n<li><strong>Verify Dead:<\/strong>&nbsp;Before switching your meter to &#8220;Insulation&#8221; mode, use the standard AC\/DC Voltage setting to measure the circuit.&nbsp;<strong>The reading must be 0V.<\/strong><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">2. Discharge Capacitive Loads<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>The Hidden Danger:<\/strong>&nbsp;Long cables, motor windings, and capacitors store energy even after power is cut.<\/li>\n\n\n\n<li><strong>Action:<\/strong>&nbsp;Use a discharge resistor or a specialized discharge rod to drain energy to the ground. Ensure no residual voltage remains.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">3. Select the Right Instrument<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>The Standard Meter Trap:<\/strong>&nbsp;A standard multimeter\u2019s &#8220;Ohm&#8221; (\u03a9) setting uses only ~3V. It cannot detect insulation failures that only appear under high voltage.<\/li>\n\n\n\n<li><strong>The Solution:<\/strong>&nbsp;You must use a&nbsp;<strong>Megohmmeter<\/strong>&nbsp;or an&nbsp;<strong>Insulation Multimeter<\/strong>&nbsp;(like the&nbsp;<strong>Honeytek HK505<\/strong>&nbsp;or&nbsp;<strong>HK705<\/strong>).<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">4. Inspect Leads and Settings<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Self-Check:<\/strong>&nbsp;Verify the meter reads &#8220;\u221e&#8221; (Infinity) when open and &#8220;0&#8221; when leads are shorted.<\/li>\n\n\n\n<li><strong>Lead Integrity:<\/strong>&nbsp;Ensure test leads have no cracks. Use leads rated for the test voltage (e.g., 1000V CAT III\/IV).<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Phase 2: Standard Wiring &amp; Testing Procedure<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Expertise (E):<\/strong>&nbsp;<em>Correct connection prevents damage to the meter and the technician.<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Terminal Selection<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>L (Line):<\/strong>&nbsp;Connects to the conductor being tested.<\/li>\n\n\n\n<li><strong>E (Earth):<\/strong>&nbsp;Connects to the ground or chassis.<\/li>\n\n\n\n<li><strong>G (Guard &#8211; Optional):<\/strong>&nbsp;Used on models like the&nbsp;<strong>HK4432<\/strong>&nbsp;series to bypass surface leakage currents for higher precision.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">2. The &#8220;Earth-First&#8221; Connection Rule<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To minimize shock risk, always follow this sequence:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Connect the Black Lead (E)<\/strong>&nbsp;to the Ground\/Earth terminal first.<\/li>\n\n\n\n<li><strong>Connect the Red Lead (L)<\/strong>&nbsp;to the conductor second.<br><em>Why? If the Red lead is live and you touch the Black lead while connecting it, you could be shocked.<\/em><\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">3. Isolation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ensure the circuit under test is isolated from other components (lightning arrestors, capacitors, circuit boards). Testing a circuit with these connected will give false readings or damage the components.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Phase 3: The Testing Process (Hands-Off)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Experience (E):<\/strong>&nbsp;<em>Insulation resistance is dynamic. It changes with time and environment.<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Hands Off<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Once the test begins,&nbsp;<strong>do not touch<\/strong>&nbsp;the metal probe tips or the equipment. The meter is actively outputting high voltage (e.g., 1000V).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. The 1-Minute Rule<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Do not just take a snapshot reading. Hold the test button for&nbsp;<strong>60 seconds<\/strong>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>Why?<\/em>&nbsp;Insulation has &#8220;Dielectric Absorption.&#8221; The resistance reading usually rises slowly as the material polarizes. The 1-minute reading is the industry standard for accuracy.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">3. Choose the Correct Voltage<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Follow this general rule to avoid damaging insulation:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Equipment &lt; 100V:<\/strong>&nbsp;Test at 250V.<\/li>\n\n\n\n<li><strong>Equipment 100V\u2013500V:<\/strong>&nbsp;Test at 500V.<\/li>\n\n\n\n<li><strong>Equipment &gt; 500V:<\/strong>&nbsp;Test at 1000V.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">4. Environmental Corrections<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">High humidity and temperature lower resistance readings. If testing in a damp environment, record the conditions. A &#8220;fail&#8221; in high humidity might be a &#8220;pass&#8221; once dried out.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Phase 4: Post-Test Safety (The &#8220;Discharge&#8221; Step)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Authoritativeness (A):<\/strong>&nbsp;<em>The test isn&#8217;t over when you release the button.<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Wait for Auto-Discharge<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Do not disconnect the leads immediately.<\/strong>&nbsp;Modern Honeytek testers (like the&nbsp;<strong>HK4432D<\/strong>) have an&nbsp;<strong>Auto-Discharge function<\/strong>. Watch the screen; voltage will drop rapidly. Wait until it reads &lt;30V.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Verification<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For large capacitive loads (long cables), double-check with a voltage tester to ensure the &#8220;ghost voltage&#8221; is gone before touching the terminals.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Disconnect in Reverse<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Disconnect the&nbsp;<strong>Red Lead (L)<\/strong>&nbsp;first.<\/li>\n\n\n\n<li>Disconnect the&nbsp;<strong>Black Lead (E)<\/strong>&nbsp;last.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Phase 5: Common Fatal Mistakes to Avoid<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Testing Live Circuits:<\/strong>&nbsp;Applying an insulation test to a live line will likely blow the meter&#8217;s fuse or cause an arc flash.&nbsp;<strong>Always verify 0V first.<\/strong><\/li>\n\n\n\n<li><strong>Using Standard Ohms:<\/strong>&nbsp;Do not write &#8220;Insulation OK&#8221; based on a standard multimeter reading. It is negligent and dangerous.<\/li>\n\n\n\n<li><strong>Wrong Voltage Selection:<\/strong>&nbsp;Testing a 24V data cable with 1000V will fry the electronics. Testing a 1000V solar string with 250V will miss potential faults.<\/li>\n\n\n\n<li><strong>Touching Before Discharge:<\/strong>&nbsp;The most common injury comes from touching the cable immediately after testing, acting as the ground path for the stored charge.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Phase 6: Quick Field Workflow (For Solar\/PV Sites)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em>A simplified checklist for your Job Safety Analysis (JSA).<\/em><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Isolate:<\/strong>&nbsp;Open AC\/DC disconnects. LOTO the switchgear.<\/li>\n\n\n\n<li><strong>Verify:<\/strong>&nbsp;Use a DMM Voltage mode to confirm 0V on the string.<\/li>\n\n\n\n<li><strong>Select:<\/strong>&nbsp;Set Honeytek meter to Insulation Mode (e.g., 1000V for a 600V system).<\/li>\n\n\n\n<li><strong>Connect:<\/strong>&nbsp;Clip Black lead to Racking\/Ground. Clip Red lead to Shorted PV Positive\/Negative.<\/li>\n\n\n\n<li><strong>Test:<\/strong>&nbsp;Press and lock the &#8220;Test&#8221; button. Wait 1 minute. Record value.<\/li>\n\n\n\n<li><strong>Discharge:<\/strong>&nbsp;Release button. Wait for display voltage to drop to zero.<\/li>\n\n\n\n<li><strong>Disconnect:<\/strong>&nbsp;Remove Red lead, then Black lead.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Recommended Gear: Honeytek Insulation Series<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To perform these tests safely, you need equipment rated for the job. Honeytek offers a range of high-precision instruments.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Honeytek <a href=\"https:\/\/honeytek.com\/product\/hk505-6000-counts-trms-handheld-insulation-tester\/\" data-type=\"product\" data-id=\"2391\">HK505<\/a> \/ HK705 (<a href=\"https:\/\/honeytek.com\/insulation-testers-manufacturer\/\" data-type=\"page\" data-id=\"2490\">Insulation Multimeters<\/a>)<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Best For:<\/strong>&nbsp;HVAC technicians and General Electricians.<\/li>\n\n\n\n<li><strong>Features:<\/strong>&nbsp;Combines a full True-RMS Multimeter with an Insulation Tester. No need to carry two meters.<\/li>\n\n\n\n<li><strong>Specs:<\/strong>&nbsp;Test voltages up to 1000V, Auto-discharge, Live circuit detection.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Honeytek <a href=\"https:\/\/honeytek.com\/product\/hk4432a-6000-counts-portable-insulation-tester\/\" data-type=\"product\" data-id=\"2465\">HK4432 <\/a>Series (Portable Insulation Testers)<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Best For:<\/strong>&nbsp;Industrial maintenance, Solar Farms, and High-Voltage Cable testing.<\/li>\n\n\n\n<li><strong>Features:<\/strong>\n<ul class=\"wp-block-list\">\n<li><strong>HK4432C:<\/strong>&nbsp;Digital precision with analog bar graph.<\/li>\n\n\n\n<li><strong>High Range:<\/strong>&nbsp;Measures up to Giga-Ohms (G\u03a9).<\/li>\n\n\n\n<li><strong>External Power:<\/strong>&nbsp;Support for extended testing sessions.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">FAQ: Frequently Asked Questions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1: Can I use the HK505 to test a live circuit?<\/strong><br><strong>A:<\/strong>&nbsp;No. Insulation resistance testing is a &#8220;dead test.&#8221; The circuit must be de-energized. However, the HK505 has built-in protection that alerts you if it detects voltage on the line before the test starts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2: What is the minimum acceptable resistance value?<\/strong><br><strong>A:<\/strong>&nbsp;A general rule of thumb is&nbsp;<strong>1 M\u03a9 per 1000V<\/strong>&nbsp;of operating voltage, with a 1 M\u03a9 absolute minimum. However, for modern equipment, values are typically in the 100 M\u03a9 to G\u03a9 range.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3: Why use the &#8220;G&#8221; (Guard) terminal on the HK4432?<\/strong><br><strong>A:<\/strong>&nbsp;The G terminal is used to divert surface leakage current away from the measurement circuit. This is critical when testing dirty or wet cables to get an accurate reading of the&nbsp;<em>internal<\/em>&nbsp;insulation resistance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4: How does the &#8220;Auto-Discharge&#8221; feature work?<\/strong><br><strong>A:<\/strong>&nbsp;After the test, the cable acts like a charged battery. The Honeytek meter internally connects a resistor across the terminals to safely drain this energy so it doesn&#8217;t shock you when you disconnect the leads.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Partner with Honeytek<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Looking for Professional Test Instruments?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Honeytek is a leading manufacturer of Digital Multimeters, Clamp Meters, and Insulation Testers. We are committed to safety, precision, and durability.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Global Distribution:<\/strong>&nbsp;We are actively recruiting agents worldwide.<\/li>\n\n\n\n<li><strong>OEM\/ODM Services:<\/strong>&nbsp;We provide full customization for your brand, from housing color to firmware features.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/honeytek.com\/contact\/\" data-type=\"page\" data-id=\"529\"><strong>[\ud83d\udc49 Contact Our Sales Team for an OEM Quote]<\/strong><br><\/a><strong><a href=\"https:\/\/honeytek.com\/download-pdf\/\" data-type=\"link\" data-id=\"https:\/\/honeytek.com\/download-pdf\/\">[\ud83d\udce5 Download the HK4432 Series Datasheet]<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>You May Also Be Interested In:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/honeytek.com\/product\/hk4432a-6000-counts-portable-insulation-tester\/\">HK4432A 6000 Counts Portable Insulation Tester<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/honeytek.com\/product\/hk4432b-6000-counts-1250v-portable-insulation-tester\/\">HK4432B 6000 Counts 1250V Portable Insulation Tester<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/honeytek.com\/product\/hk4432c-6000-counts-2500v-portable-insulation-tester\/\">HK4432C 6000 Counts 2500V Portable Insulation Tester<\/a><\/li>\n<\/ul>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Unlike standard resistance measurements, testing&nbsp;Insulation Resistance (IR)&nbsp;involves injecting high voltage (often 500V or 1000V) into a circuit to stress-test the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5311,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1,68],"tags":[139],"class_list":["post-5309","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs","category-news-events","tag-insulation-resistance-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/posts\/5309","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/comments?post=5309"}],"version-history":[{"count":6,"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/posts\/5309\/revisions"}],"predecessor-version":[{"id":5454,"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/posts\/5309\/revisions\/5454"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/media\/5311"}],"wp:attachment":[{"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/media?parent=5309"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/categories?post=5309"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/honeytek.com\/ru\/wp-json\/wp\/v2\/tags?post=5309"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}