HK689C Professional 1000A True RMS Clamp Meter

Features

  • 1000A AC current measurement: Four selectable ranges—6A, 60A, 600A and 1000A—for checking electrical loads.
  • True RMS measurement: Supports AC troubleshooting where waveforms may be non-sinusoidal.
  • 1000V AC/DC voltage measurement: Covers low-voltage signals through higher-voltage electrical measurements.
  • VFD and motor testing functions: Combines VFD mode, inrush current testing and peak hold for equipment diagnostics.
  • LoZ AC/DC mode: Helps distinguish induced ghost voltages from a connected voltage source.
  • DC microamp measurement: Dedicated 200μA and 2000μA ranges for low-current testing.
  • Multiple diagnostic functions: Includes NCV, live wire recognition, phase sequence detection and a 30mA RCD test function.
  • Convenient reading and recording: Backlight, flashlight, analog bar, data hold, relative mode and MAX/MIN/AVG functions.

El HK689C True RMS AC clamp meter combines AC current measurement up to 1000A with AC/DC voltage measurement up to 1000V. Its 6A, 60A, 600A and 1000A AC current ranges support electrical troubleshooting, equipment maintenance and load checks across a variety of applications.

For motor and drive diagnostics, the HK689C includes VFD mode, inrush current testing and peak hold. LoZ AC/DC voltage measurement helps reduce the influence of ghost voltages, while NCV detection and live wire recognition support preliminary wiring checks.

Additional functions include DC microamp measurement, resistance, capacitance, frequency and temperature testing. A backlit LCD, analog bar display and built-in flashlight make readings easier to view in dim work areas.

Características principales

  • 1000A AC current measurement: Four selectable ranges—6A, 60A, 600A and 1000A—for checking electrical loads.
  • True RMS measurement: Supports AC troubleshooting where waveforms may be non-sinusoidal.
  • 1000V AC/DC voltage measurement: Covers low-voltage signals through higher-voltage electrical measurements.
  • VFD and motor testing functions: Combines VFD mode, inrush current testing and peak hold for equipment diagnostics.
  • LoZ AC/DC mode: Helps distinguish induced ghost voltages from a connected voltage source.
  • DC microamp measurement: Dedicated 200μA and 2000μA ranges for low-current testing.
  • Multiple diagnostic functions: Includes NCV, live wire recognition, phase sequence detection and a 30mA RCD test function.
  • Convenient reading and recording: Backlight, flashlight, analog bar, data hold, relative mode and MAX/MIN/AVG functions.

Especificaciones técnicas

Accuracy is expressed as ±(% of reading + digits).

MeasurementGamaPrecisión
DC voltage600mV±(0.5% + 3 digits)
DC voltage6V / 60V / 600V±(0.5% + 2 digits)
DC voltage1000 V±(0.8% + 5 digits)
AC voltage6V / 60V±(1.0% + 5 digits)
AC voltage600V±(0.8% + 5 digits)
AC voltage1000 V±(1.0% + 5 digits)
AC current6A / 60A / 600A / 1000A±(2.5% + 5 digits)
DC microamp current200μA / 2000μA±(1.2% + 5 digits)
Resistencia600Ω±(1.0% + 2 digits)
Capacitancia600nF / 6μF / 60μF / 600μF±(4.0% + 5 digits)
Capacitancia6mF±(10% + 5 digits)
Frecuencia5Hz–1MHz±(0.1% + 5 digits)
Temperatura−40°C to 0°C±(5% + 4 digits)
TemperaturaDe 0 °C a 400 °C±(2.0% + 3 digits)
Temperature*−4°F to 50°F±(5% + 4 digits)
Temperature*De 50 °F a 750 °F±(2.0% + 5 digits)

Functions and General Specifications

CaracterísticaEspecificaciones
True RMSSí
Número de elementos mostrados5999 + 1999
Selección de rangoAuto / Manual
LoZ AC/DC voltageUp to 1000V
VFD modeSí
Inrush current testSí
Peak holdSí
MAX / MIN / AVGSí
Retención de datosSí
Relative modeSí
Diode testSí
Continuity buzzerSí
Non-contact voltage detection (NCV)Sí
Live wire recognitionSí
Phase sequence detectionSí
RCD test30mA test function
Analog bar displaySí
Retroiluminación de la pantalla LCDSí
Built-in flashlightSí
Auto power offSí
Measurement category ratingCAT III 1000 V / CAT IV 600 V
Power supply3 × 1.5V AA batteries

Aplicaciones

  • Electrical installation and maintenance: Measure AC loads and AC/DC voltage when inspecting circuits and equipment.
  • Motor startup troubleshooting: Use inrush current testing and peak hold to investigate startup behavior.
  • Variable frequency drive maintenance: Use VFD mode when checking drive-controlled equipment.
  • HVAC equipment servicing: Combine AC current, capacitance and temperature measurements for equipment checks.
  • Facility maintenance: Perform continuity, diode and resistance tests during routine electrical troubleshooting.
  • Three-phase installation checks: Use phase sequence detection when checking phase order.
Shanghai Office

Shenzhen Factory

U.S. Office

Get a Free Quote Now!

 Send us your contact details or give us a quick call — our team will respond within 24 hours, guaranteed.

Contact Form Demo

Preguntas frecuentes

Yes, Honeytek supports OEM/ODM customization, including logo printing, packaging design, and parameter adjustments (e.g., measurement ranges, functions, or display options) to meet specific client requirements.

Standard models usually ship within 15–30 days after order confirmation. Customized orders may require additional time depending on specifications.

Yes, our DMMs comply with CE, RoHS, and other international safety/quality standards. Specific certifications vary by model—contact us for details.

MOQ starts at 500 units for standard customization (e.g., logo/packaging). Larger parameter modifications may require higher quantities.

All DMMs undergo rigorous calibration and testing. We provide calibration certificates (optional) and recommend periodic recalibration for precision.

We provide a 1–2 year warranty, technical support, and repair services. Spare parts (e.g., test leads, fuses) are also available.

Get a Free Quote Now!

Get a Free Quote Now! 弹窗