The HK235C Two-Pole Voltage and Continuity Tester is designed for fast electrical safety checks in residential, commercial and industrial installations. It combines a stepped LED voltage indicator with an LCD numerical display, allowing technicians to recognize standard voltage levels at a glance while viewing a more detailed measurement.
The tester covers 1-1000V AC and 1-1000V DC through the LCD, with LED indication at commonly used voltage steps. Optical and acoustic continuity feedback helps locate open circuits, damaged wiring and incomplete connections. For three-phase work, the HK235C includes phase-sequence testing, single-pole voltage detection and a 30mA RCD trip-test function.
A polarity indicator, automatic voltage self-test, vibration alert and silent operating mode make the instrument adaptable to different working environments. Its IP65 enclosure and CAT III 1000V / CAT IV 600V rating support field use around distribution systems and electrical service equipment.
Features
- Dual LED and LCD presentation for quick identification and detailed voltage readings.
- AC and DC measurement from 1V to 1000V.
- Optical and acoustic continuity test covering 0-100kΩ.
- Phase-sequence detection for 50-60Hz three-phase systems.
- Single-pole testing from 100V to 690V.
- Integrated 30mA RCD trip test at 230V.
- Vibration alert for noisy or visibility-restricted locations.
- Silent mode for environments where an acoustic alarm is unsuitable.
- Polarity indication and automatic voltage self-test.
- IP65 protection with an integrated work light.
Technical Specifications
| Specification | HK235C |
|---|---|
| Measurement Technology | True RMS |
| Display | LED and LCD |
| LCD Voltage Range | 1-1000V AC/DC |
| LED Voltage Steps | 12, 24, 48, 120, 240, 480, 690 and 1000V |
| Frequency Response | 0/40-1000Hz |
| LED Response Time | ≤0.5 seconds |
| LCD Response Time | ≤1 second |
| Continuity Test | Optical and acoustic, 0-100kΩ |
| Resistance Measurement | 0.1kΩ-300kΩ |
| Phase-Sequence Test | 50-60Hz, 57-400V |
| Single-Pole Test | 100-690V, 50-400Hz |
| RCD Trip Test | 30mA at 230V |
| Polarity Indication | Supported |
| Voltage Self-Test | Supported |
| Data Hold | Supported |
| Vibration Alert | Supported |
| Silent Mode | Supported |
| Automatic Range Selection | Supported |
| Automatic Power-Off | Supported |
| Flashlight | Supported |
| Low-Battery Indication | Supported |
| Display Area | 24 × 17.4mm |
| Protection Rating | IP65 |
| Overvoltage Category | CAT III 1000V / CAT IV 600V |
| Certifications Listed | VDE, GS and CE |
| Battery | 2 × 1.5V AAA |
| Dimensions | 250 × 83.5 × 45mm |
| Weight | Approximately 355g |
Application
- Verifying voltage before electrical installation or repair
- Checking sockets, switches and distribution boards
- Finding broken or incomplete conductor paths
- Confirming polarity in AC and DC circuits
- Testing phase order during motor installation
- Performing preliminary RCD operating checks
- Maintaining commercial building electrical systems
FAQ
Does the HK235C display an exact voltage value?
It combines an LCD numerical reading with stepped LED indicators. The LEDs provide immediate voltage-level recognition, while the LCD supplies a more detailed result.
Can it test three-phase systems?
Yes. It supports phase-sequence testing from 57V to 400V at 50-60Hz.
Is the HK235C suitable for outdoor work?
Its IP65 enclosure provides protection against dust and water jets. Users must still follow all applicable electrical safety and environmental procedures.