HK39F 6000 Counts 600V/600mA Pocket TRMS Multimeter

Highlights:

  • 6,000-count display: Offers finer displayed resolution than a standard 4,000-count pocket meter.
  • True RMS technology: Supports more dependable AC testing on both conventional and non-linear electrical loads.
  • Optional 600 A AC clamp measurement: Extends the meter’s application range when paired with the HK19 current clamp probe.
  • Resistance measurement up to 60 MΩ: Useful for inspecting high-value resistors and comparing resistance conditions in electrical assemblies.
  • Capacitance capacity up to 60 mF: Supports testing across nanofarad, microfarad and millifarad ranges.
  • 600 V AC/DC voltage capability: Covers common electrical maintenance and equipment-diagnostic requirements.
  • Automatic ranging: Reduces manual range changes and makes routine measurements faster.
  • NCV and live-wire functions: Assist with locating potentially energized wires before direct testing.
  • Continuity and diode modes: Enable quick checks of cables, contacts, fuses and semiconductor junctions.
  • Hold, backlight and flashlight functions: Improve usability inside cabinets and restricted working spaces.
  • Compact 130 g construction: Easy to carry as part of a mobile service toolkit.
  • CAT III 600 V classification: Intended for use within its marked category, voltage and manufacturer-specified operating conditions.

The HK39F TRMS Pocket Auto-Range Digital Multimeter combines a high-resolution 6,000-count display with everyday electrical testing functions in a lightweight, portable body. It is intended for electrical maintenance, equipment servicing, electronics inspection and field diagnostics where clear readings and broad resistance or capacitance coverage are important.
The instrument measures AC/DC voltage up to 600 V, direct current up to 600 mA and alternating current up to 600 mA through its standard meter inputs. It can also measure AC current up to 600 A when used with the optional HK19 current clamp probe. This expandable current-measurement capability allows the HK39F to cover tasks ranging from low-current electronic circuits to larger AC conductors without placing the multimeter directly in series with the load.
Its 60 MΩ resistance ceiling and capacitance range up to 60 mF make it well suited to component testing, insulation-related diagnostic comparisons and maintenance checks involving larger capacitors. Frequency and duty-cycle functions provide additional information when inspecting control signals and electrical outputs.
For fast day-to-day work, the HK39F includes automatic ranging, True RMS measurement, NCV detection, live-wire recognition, diode test, audible continuity, data hold, LCD backlight and an integrated flashlight. The meter is powered by two AAA batteries and weighs approximately 130 g.

Key Features and Benefits

  • 6,000-count display: Offers finer displayed resolution than a standard 4,000-count pocket meter.
  • True RMS technology: Supports more dependable AC testing on both conventional and non-linear electrical loads.
  • Optional 600 A AC clamp measurement: Extends the meter’s application range when paired with the HK19 current clamp probe.
  • Resistance measurement up to 60 MΩ: Useful for inspecting high-value resistors and comparing resistance conditions in electrical assemblies.
  • Capacitance capacity up to 60 mF: Supports testing across nanofarad, microfarad and millifarad ranges.
  • 600 V AC/DC voltage capability: Covers common electrical maintenance and equipment-diagnostic requirements.
  • Automatic ranging: Reduces manual range changes and makes routine measurements faster.
  • NCV and live-wire functions: Assist with locating potentially energized wires before direct testing.
  • Continuity and diode modes: Enable quick checks of cables, contacts, fuses and semiconductor junctions.
  • Hold, backlight and flashlight functions: Improve usability inside cabinets and restricted working spaces.
  • Compact 130 g construction: Easy to carry as part of a mobile service toolkit.
  • CAT III 600 V classification: Intended for use within its marked category, voltage and manufacturer-specified operating conditions.

HK39F Technical Specifications

MeasurementRangeAccuracy
DC Voltage60 mV / 600 mV / 6 V / 60 V±(0.5% + 5 digits)
DC Voltage600 V±(0.8% + 5 digits)
AC Voltage60 mV / 600 mV / 6 V / 60 V±(1.0% + 3 digits)
AC Voltage600 V±(1.2% + 5 digits)
DC Current600 µA / 6000 µA / 60 mA±(1.0% + 5 digits)
DC Current600 mA±(2.0% + 5 digits)
AC Current600 µA / 6000 µA / 60 mA±(1.5% + 5 digits)
AC Current600 mA±(2.5% + 5 digits)
AC Current with optional clampUp to 600 A±(2.5% + 5 digits)
Resistance600 Ω / 6 kΩ / 60 kΩ / 600 kΩ / 6 MΩ±(1.0% + 5 digits)
Resistance60 MΩ±(1.2% + 8 digits)
Capacitance1 nF / 10 nF±(4.0% + 25 digits)
Capacitance100 nF / 1 µF / 10 µF / 100 µF±(4.0% + 15 digits)
Capacitance1 mF / 60 mF±(5.0% + 25 digits)
Frequency10 Hz / 100 Hz / 1 kHz / 10 kHz±(0.5% + 2 digits)
Duty Cycle0.1%–99.9%±(1.2% + 3 digits)

General Specifications

ItemHK39F Specification
Measurement methodTrue RMS
Display6,000-count LCD
Range selectionAutomatic
Standard AC current rangeUp to 600 mA
Clamp-assisted AC currentUp to 600 A with optional HK19 probe
Non-contact voltage detectionYes
Live-wire recognitionYes
Diode testYes
Continuity buzzerYes
Data holdYes
LCD backlightYes
Built-in flashlightYes
Auto power-offYes
Battery test1.5 V
Temperature measurementNo
Safety categoryCAT III 600 V
Power supply2 × 1.5 V AAA batteries
Product dimensions119 × 65 × 30 mm
Product weight130 g
Carton quantity60 pieces
Carton dimensions47 × 31.5 × 34.7 cm
Net/Gross weight17.5 kg / 18.5 kg

Optional HK19 Current Clamp Probe

ItemSpecification
Jaw opening30 mm
AC current ranges600 mV / 600 A
Output100 mV/100 A AC; 10 mV/10 A AC; 1 mV/1 A AC
Safety ratingCAT II 600 V / CAT III 300 V
Maximum rated currentAC 20 A, as stated in the supplied specification image
ApplicationOptional accessory for compatible digital multimeters

Specification review note: The supplied HK19 table separately states “600 mV/600 A” and “Max Rated Current AC 20 A.” These two statements appear potentially inconsistent. Confirm the clamp’s official manual or engineering data before publishing the maximum-current claim.

Typical Applications

Distribution Panel Checks

With suitable probes and safe working practices, the HK39F can be used to measure voltage, locate live conductors and check continuity in distribution and control panels.

Clamp-Assisted AC Current Inspection

The optional HK19 probe allows current to be measured around a conductor without opening the circuit, subject to the probe’s verified current rating and operating instructions.

Electronic Component Testing

Its 6,000-count display, 60 MΩ resistance capacity and 60 mF capacitance range support detailed checking of resistors, capacitors, diodes and low-current circuits.

Power Supply and Control-System Maintenance

Frequency, duty-cycle and True RMS functions help technicians evaluate power outputs and basic control signals in equipment-maintenance environments.

Workshop and On-Site Service

The backlight, flashlight, auto-range operation and compact dimensions make the HK39F useful for repair benches, toolboxes and mobile service calls.


HK39D vs. HK39F Comparison

Comparison PointHK39DHK39F
Display count4,000 counts6,000 counts
True RMSYesYes
Maximum AC/DC voltage600 V600 V
Standard maximum DC current400 mA600 mA
Standard maximum AC current400 mA600 mA
Optional clamp measurementNot specifiedUp to 600 A AC, subject to HK19 rating verification
Maximum resistance40 MΩ60 MΩ
Maximum capacitance40 mF60 mF
Frequency rangeUp to 10 kHzUp to 10 kHz
Duty-cycle measurement0.1%–99.9%0.1%–99.9%
Temperature measurement-20°C to 1000°CNot available
NCV detectionYesYes
Live-wire recognitionYesYes
Diode and continuity testsYesYes
Backlight and flashlightYesYes
Safety ratingCAT III 600 VCAT III 600 V
Dimensions119 × 65 × 30 mm119 × 65 × 30 mm
Weight130 g130 g
Best suited forElectrical, electronics and temperature troubleshootingHigher-resolution electrical testing and optional clamp-assisted AC current checks

Which Model Should You Choose?

Choose the HK39D when temperature measurement is part of the job. Its -20°C to 1000°C capability makes it the more suitable option for HVAC servicing, heating-system checks, appliance diagnostics and maintenance tasks that require both electrical and temperature readings.

Choose the HK39F when display resolution, wider resistance and capacitance ranges, or clamp-assisted AC current measurement are more important. Its 6,000-count screen, 60 MΩ resistance range and optional current clamp provide greater flexibility for electrical and electronics diagnostics.

Shanghai Office

Shenzhen Factory

U.S. Office

Get a Free Quote Now!

 Send us your contact details or give us a quick call — our team will respond within 24 hours, guaranteed.

Contact Form Demo

Frequently Asked Questions

Yes, Honeytek supports OEM/ODM customization, including logo printing, packaging design, and parameter adjustments (e.g., measurement ranges, functions, or display options) to meet specific client requirements.

Standard models usually ship within 15–30 days after order confirmation. Customized orders may require additional time depending on specifications.

Yes, our DMMs comply with CE, RoHS, and other international safety/quality standards. Specific certifications vary by model—contact us for details.

MOQ starts at 500 units for standard customization (e.g., logo/packaging). Larger parameter modifications may require higher quantities.

All DMMs undergo rigorous calibration and testing. We provide calibration certificates (optional) and recommend periodic recalibration for precision.

We provide a 1–2 year warranty, technical support, and repair services. Spare parts (e.g., test leads, fuses) are also available.

Get a Free Quote Now!

Get a Free Quote Now! 弹窗