HK88B 6000 Counts TRMS Auto-Range Digital Multimeter with EBTN Display

Highlights:

  • 5,999 counts LCD for improved resolution
  • True RMS for precise AC measurements
  • Wide measurement ranges for voltage, current, resistance, and capacitance
  • Temperature measurement included (-20°C to 1000°C)
  • NCV and live wire detection for safe diagnostics
  • Relative mode and data hold function
  • Auto power-off feature
  • Full overload protection for durability
  • CAT III 1000V certified

 

Product Description

 

The HK88B Digital Multimeter is the more advanced model in the HK88 series, combining True RMS performance, auto ranging, EBTN display, wider measurement capability, and stronger North America-facing certification presentation. Compared with HK88A, it offers a higher 5999-count display, V.F.C function, a much wider temperature range, and square wave output, making it better suited for more demanding diagnostics and broader service applications.

A major selling point of the HK88B is that the supplied product sheet shows FCC and ETL (cETLus) markings for HK88B only, giving it stronger positioning for customers and distributors who value compliance visibility in North American channels. Intertek states that the ETL Listed Mark indicates a product has been independently tested and certified to applicable North American safety standards, and that it is accepted across the U.S. and Canada.

For brands, importers, and professional users, HK88B stands out as the more premium option: broader function coverage, better display count, added signal-related functions, and a more market-ready certification profile.

Key Features

  • True RMS measurement for reliable real-world testing

  • 5999-count auto-ranging display for higher resolution than HK88A

  • EBTN display for improved visibility in darker working conditions

  • FCC and ETL (cETLus) markings shown for HK88B only, strengthening its premium and North America-oriented positioning

  • NCV detection and live wire recognition for fast electrical checks

  • LoZ AC/DC helps reduce ghost-voltage false readings

  • V.F.C function for better drive-related or variable-frequency applications

  • Measures DC/AC voltage, DC/AC current, resistance, capacitance, frequency, and temperature

  • Square wave output for added testing flexibility

  • Wide temperature range up to 1000°C / 1832°F

  • Analog bar display, MAX/MIN, data hold, relative mode, and fused alarm

  • CAT III 600 V safety rating

Specifications

ItemHK88B
DC Voltage600mV / 4V / 4V* : ±(0.5% + 3d); 600V: ±(0.8% + 5d)
AC Voltage6V / 60V / 600V: ±(1.0% + 5d)
DC Current600μA / 6000μA / 60mA: ±(1.0% + 5d); 600mA: ±(2.0% + 5d); 6A / 10A: ±(3.0% + 5d)
AC Current600μA / 6000μA / 60mA: ±(1.8% + 5d); 600mA: ±(2.5% + 5d); 6A / 10A: ±(3.0% + 5d)
Resistance600Ω / 6kΩ / 60kΩ / 600kΩ / 6MΩ: ±(1.0% + 5d); 60MΩ: ±(1.2% + 8d)
Capacitance60nF: ±(4.0% + 25d); 600nF / 6μF / 60μF / 600μF: ±(4.0% + 15d); 6mF / 60mF: ±(10% + 5d)
Frequency60Hz / 600Hz / 6kHz / 60kHz / 600kHz / 6MHz / 10MHz: ±(0.5% + 4d)
Temperature (°C)-20°C to 0°C: ±4°C; 0°C to 400°C: ±(2.0% + 3d); 400°C to 1000°C: ±(3.0% + 3d)
Temperature (°F)-4°F to 50°F: ±5°F; 50°F to 750°F: ±(2.0% + 5d); 750°F to 1832°F: ±(3.0% + 5d)
Square Wave Output50 / 100 / 200 / 300 / 400 / 500 / 600 / 700 / 800 / 900 Hz / 1k / 2k / 4k / 5kHz: ±(1.0% + 5d)
True RMSYes
Display Count5999
Diode TestYes
Continuity BuzzerYes
NCVYes
Live Wire RecognitionYes
Analog Bar DisplayYes
LoZ AC/DCYes
V.F.CYes
LCD TypeEBTN
MAX/MINYes
Data HoldYes
Relative ModeYes
Auto Power OffYes
Fused AlarmYes
Range SelectionAuto
Safety RatingCAT III 600V
Battery Type1.5V AAA × 2
Product Size155 × 72 × 45 mm
Product Weight254 g

*The DC-voltage sub-range is written exactly as shown on your supplied specification image.

Applications

  • Professional electrical maintenance

  • HVAC and industrial service work

  • Electrical installation testing

  • Variable-frequency drive related checks

  • Signal and square-wave related diagnostics

  • Broader temperature testing in field service and maintenance

  • North America-focused distribution or OEM/ODM presentation

Popular FAQ

1. What is the main difference between HK88A and HK88B?
HK88B is the upgraded model. It offers a 5999-count display, V.F.C, square wave output, a much wider temperature range, and the supplied sheet shows FCC and ETL markings for HK88B only.

2. Why is HK88B stronger for premium-market positioning?
Because it combines broader functions with a stronger compliance-facing presentation. The supplied material highlights FCC and ETL (cETLus) markings on HK88B, which is especially valuable for North America-oriented sales channels. Intertek says the ETL Listed Mark indicates independent testing and certification to applicable North American safety standards.

3. Does HK88B support non-contact voltage detection?
Yes. It includes NCV and live wire recognition for quick field checks.

4. What is the benefit of V.F.C on HK88B?
V.F.C helps improve measurement usefulness in applications involving variable-frequency environments, making HK88B better suited for more advanced service work.

5. Can HK88B measure high temperatures?
Yes. HK88B measures up to 1000°C or 1832°F, making it much more versatile than HK88A for temperature-related testing.

6. Does HK88B have square wave output?
Yes. This is one of its differentiating features and gives it added flexibility in diagnostic and signal-related applications.

7. Is HK88B still compact enough for daily field work?
Yes. Despite its broader feature set, HK88B keeps the same compact body size as HK88A and remains easy to carry for daily use.

Recommended Positioning

HK88A
A practical all-rounder for daily electrical work, offering True RMS, LoZ, NCV, live wire recognition, capacitance, frequency, and basic temperature measurement.

HK88B
A more advanced, premium-positioned model for customers who want more capability, broader measurement coverage, higher display resolution, and stronger compliance-facing presentation through the FCC + ETL highlighted version.


 Comparison – HK88A vs HK88B

FeatureHK88AHK88B
Display Count4,0006,000
True RMS✔️✔️
DC Voltage RangeUp to 600VUp to 600V
AC Voltage RangeUp to 600VUp to 600V
Resistance RangeUp to 40MΩUp to 60MΩ
Temperature MeasurementLimited (0-50°C)Full-Range (-20°C to 1000°C)
Square Wave Output✔️
LoZ (Low Impedance)✔️✔️
NCV / Live Wire Recognition✔️✔️
EBTN Display✔️✔️
CAT RatingCAT III 600VCAT III 600V
Best ForGeneral electronics, home use, and basic professional needs.Professional use, advanced diagnostics, and specialized testing.
 
Shanghai Office

Shenzhen Factory

U.S. Office

Get a Free Quote Now!

 Send us your contact details or give us a quick call — our team will respond within 24 hours, guaranteed.

Contact Form Demo

Frequently Asked Questions

Yes, Honeytek supports OEM/ODM customization, including logo printing, packaging design, and parameter adjustments (e.g., measurement ranges, functions, or display options) to meet specific client requirements.

Standard models usually ship within 15–30 days after order confirmation. Customized orders may require additional time depending on specifications.

Yes, our DMMs comply with CE, RoHS, and other international safety/quality standards. Specific certifications vary by model—contact us for details.

MOQ starts at 500 units for standard customization (e.g., logo/packaging). Larger parameter modifications may require higher quantities.

All DMMs undergo rigorous calibration and testing. We provide calibration certificates (optional) and recommend periodic recalibration for precision.

We provide a 1–2 year warranty, technical support, and repair services. Spare parts (e.g., test leads, fuses) are also available.

Get a Free Quote Now!

Get a Free Quote Now! 弹窗